| PRELIMINARY SPECIFICATIONS |
| Dimensions |
19" W X 5.25" H X 14" D |
| Line Voltage Requirements |
85 VAC - 260 VAC, 50/60 Hz |
| Acessories
Included |
(1) 6 ft. (2m) UL/CSA line cord
(1) user manual
(1) software CD
(1) USB cable |
| Front Panel
Controls |
| Power Switch |
(1) rocker switch |
| Monitor Mode Select |
(1) momentary push button |
| Monitor Channel
Select |
(9 or 11) momentary push buttons |
| Monitor Volume |
(1) rotary potentiometer |
| Test Lead Connections |
(2) test point jacks |
| Bypass Mode Select
Switch |
(1) slide switch |
| Indicators |
| Power Indicator |
(1) green LED |
| Monitor Mode Indicators |
(1) green LED and (1) yellow LED |
| Processor Channel
Indicators |
(9 or 11) green LEDs |
| Amplifier Channel
Indicators |
(9 or 11) yellow LEDs |
| Load Fault Indicator |
(1) red LED |
| Clip Indicator |
(1) red LED |
| Bypass Mode Indicator |
(1) flashing red LED |
| Alt EQ Mode Indicator |
(1) yellowLED |
| Rear Panel
Controls |
| Bypass Crossover
Level |
(2 or 3) rotary trimpots |
| Surround EX Mode Switch |
(1) slide switch |
Analog/Digital Input
Select
(D models only) |
(1) slide switch |
| Rear panel
control connectors |
| Main Analog Input |
(1) 25 pin female D-sub connector |
| Surround Input |
(1) 25 pin female D-sub connector |
| Digital Input (D models only)
|
(1) 25 pin female D-sub connector |
| Amplifier DataPorts |
(10 or 19) 15-pin female high-density D-sub connectors |
| Control Port |
(1) USB series-B receptacle |
| Hearing Impaired
Line Output |
(1) 2 position screw-terminal connector |
| Powered Sub Line Output |
(1) 3 position screw-terminal connector |
| External Monitor Speaker Output |
(1) 2 position screw-terminal connector |
| Aux Line Level Input |
(1) 2 position screw-terminal connector |
| Alt EQ Contact Closure Input
|
(1) 2 position screw-terminal connector |
| AC Power Inlet |
(1) IEC style with fuse |
| DCM Inputs
|
| Input Stage Type |
Active balanced |
| Input Impedance |
10k ohms |
| Maximum Analog Input
Level |
+14.2 dBu (4.0 Vrms) |
| A/D Conversion |
24 bit delta-sigma 128x oversampled |
| Dataport Outputs
- Screen Channels |
| Output Level Range |
+6 dB to -18 dB in 0.1 dB steps |
| Dynamic Range |
> 105 dB |
| THD+N 20 Hz-20 kHz,
+12 dBu input level, all filters set flat |
< 0.002% |
| Frequency Response |
20 Hz-20 kHz (no filtering) |
| D/A Conversion |
24 bit delta-sigma 128x oversampled |
| Filter Topology |
24 bit digital IIR filters |
| Crossover
Filters |
Linkwitz-Riley 24 dB/octave digital filters programmablefrom
20 Hz to 20 kHz |
Parametric
EQ
(3 per channel + 3 per band) |
Digital bandpass with ±10 dB of boost/cut
programmable from 20 Hz to 20 kHz. Q is programmable in 1/10th
octave steps from 1/10 to 2 octaves |
| CD Horn EQ |
Digital shelf filter with up to 6 dB of boost
programmable from 1 kHz to 20 kHz. Available on high frequency
band only |
| Screen EQ |
Digital shelf with up to 6 dB of boost programmable
from 1 kHz to 20 kHz |
| Subsonic (highpass) Filter |
Digital high pass filter programmable from 15 Hz to 200 Hz.
Q can be programmed as 0.707 (flat) or 2 (B6 boost) |
| Allpass Filter |
2nd order allpass filter programmable from 20 Hz to 2000 Hz
(dual low band output only) |
| Channel Delay |
Programmable in 21 μs steps from 0 to 10 ms
per output |
| Polarity |
Normal, Inverted |
| Mute |
Individual mutes on each channel and band output |
| Dataport
Outputs - Surround and Subwoofer |
| Output Level Range |
+6 dB to -18 dB in 0.1 dB steps |
| Dynamic Range |
> 105 dB |
| THD+N 20 Hz-20 kHz, +12 dBu
input level, all filters set flat |
< 0.002% |
| Frequency Response |
20 Hz-20 kHz (no filtering) |
| D/A Conversion |
24 bit delta-sigma 128x oversampled |
| Filter Topology |
24 bit digital IIR filters |
Parametric EQ
(2 per channel) |
Digital bandpass with ±10 dB of boost/cut programmable
from 20 Hz to 20 kHz. Q is programmable in 1/10th octave steps
from 1/10 to 2 octaves |
| Subsonic (highpass) Filter |
Digital high pass filter programmable from 15 Hz to 200 Hz.
Q can be programmed as 0.707 (flat) or 2 (B6 boost) |
| Channel Delay |
Programmable from 0 to 150 ms per output (surrounds only)
|
| Mute |
One mute for all subwoofer outputs |
| Bass Management
|
Weighted sum of screen channels may be low pass
filtered and mixed with sub output |
| Dataport
Outputs - Aux |
| Output Level Range |
+6 dB to -18 dB in 0.1 dB steps |
| Dynamic Range |
> 105 dB |
| THD+N 20 Hz-20 kHz, +12 dBu
input level, all filters set flat |
< 0.002% |
| Frequency Response |
20 Hz-20 kHz (no filtering) |
| D/A Conversion |
24 bit delta-sigma 128x oversampled |
| Filter Topology |
24 bit digital IIR filters |
| Crossover Filters |
Linkwitz-Riley 24 dB/octave digital filters programmablefrom
20 Hz to 20 kHz |
Parametric EQ
(3 per channel + 3 per band) |
Digital bandpass with ±10 dB of boost/cut programmable
from 20 Hz to 20 kHz. Q is programmable in 1/10th octave steps
from 1/10 to 2 octaves |
| Subsonic (highpass) Filter |
Digital high pass filter programmable from 15 Hz to 200 Hz.
Q can be programmed as 0.707 (flat) or 2 (B6 boost) |
| CD Horn EQ |
Digital shelf filter with up to 6 dB of boost programmable
from 1 kHz to 20 kHz. Available on high frequency band only |
| Screen EQ |
Digital shelf with up to 6 dB of boost programmable from 1
kHz to 20 kHz |
| Channel Delay |
Programmable from 0 to 150 ms per output |
| Band Delay |
Programmable in 21 μs steps from 0 to 10 ms per output |
| Mute |
Individual mutes on each channel output |
| Surround Bass Management |
Weighted sum of surround channels may be low pass filtered
and mixed with aux output |
| Amplifier A.C.
Control |
| |
All amps power on with DCM activation |
| Emergency Bypass
Crossover |
| Filter Type |
2nd order active Butterworth, 2 or 3 way |
| Attenuation Range
(trimpot) |
0 dB to -20 dB |
| Powered Subwoofer
Output |
| Output Stage Type |
Single ended (balanced impedance) |
| Output Impedance |
50 ohms |
| Maximum Output Level |
+14.8 dBu (6Vp = 4.25 Vrms) |
| Loading Requirements
(total of remote & dataport connection) |
RMIN = 2k ohms CMAX
= 4 nF |
| Monitor Speaker
Output |
| Amplifier Output Power |
10 watt Class D amplifier |
| Frequency Response |
20 Hz-20 kHz (±2 dB) |
| Dynamic Processing |
1.5:1 Compression |
| Aux Input |
| Input Stage Type |
Active Balanced |
| Input Impedance |
10k ohms |
| Maximum Input Leve |
+14.2 dBu (4.0 Vrms) |
| Hearing Impaired
Output |
| Output Stage Type |
Single ended (balanced impedance) |
| Output Impedance |
50 ohms |
| Nominal output Level |
-11.8 dBu (200 mVrms) |
| Loading Requirements |
RMIN = 2k ohms CMAX = 4
nF |
| Contact Closure
Input |
| Input Type |
TTL Compatible or Dry Contact Closure |
| Operating Mode |
Connection to ground through a maximum impedance
of 1.3k ohmsselects alt EQ settings |
| Internal Monitor
Speaker |
| Dimensions |
4-inch full range driver |
|
|